Repository logo
 
Loading...
Profile Picture
Person

Pessôa Filho, Dalton

Search Results

Now showing 1 - 2 of 2
  • Can an Incremental Step Test Be Used for Maximal Lactate Steady State Determination in Swimming? Clues for Practice
    Publication . Espada, Mário C.; Alves, Francisco B.; Curto, Dália; Ferreira, Cátia C.; SANTOS, FERNANDO JORGE LOURENÇO DOS; Pessôa Filho, Dalton; Reis, Joana F.
    We aimed to compare the velocity, physiological responses, and stroke mechanics between the lactate parameters determined in an incremental step test (IST) and maximal lactate steady state (MLSS). Fourteen well-trained male swimmers (16.8 ± 2.8 years) were timed for 400 m and 200 m (T200). Afterwards, a 7 × 200-m front-crawl IST was performed. Swimming velocity, heart rate (HR), blood lactate concentration (BLC), stroke mechanics, and rate of perceived exertion (RPE) were measured throughout the IST and in the 30-min continuous test (CT) bouts for MLSS determination. Swimming velocities at lactate threshold determined with log-log methodology (1.34 ± 0.06 m·s −1 ) and Dmax methodology (1.40 ± 0.06 m·s −1 ); and also, the velocity at BLC of 4 mmol·L −1 (1.36 ± 0.07) were not significantly different from MLSSv, however, Bland–Altman analysis showed wide limits of agreement and the concordance correlation coefficient showed poor strength of agreement between the aforementioned parameters which precludes their interchangeable use. Stroke mechanics, HR, RPE, and BLC in MLSSv were not significantly different from the fourth repetition of IST (85% of T200), which by itself can provide useful support to daily practice of well-trained swimmers. Nevertheless, the determination of MLSSv, based on a CT, remains more accurate for exercise evaluation and prescription.
  • Effects of Pitch Size and Goalkeeper Participation on Physical Load Measures during Small-Sided Games in Sub-Elite Professional Soccer Players
    Publication . SANTOS, FERNANDO JORGE LOURENÇO DOS; Verardi, Carlos; Moraes, Mayra Grava de; Pessôa Filho, Dalton; Macedo, Anderson G.; Figueiredo, Teresa P.; Ferreira, Cátia C.; Borba, Ricardo P.; Espada, Mário
    This study sought to examine the variations of internal and external load measures in soccer players when performing different types of 4 vs. 4 small-sided games (SSGs). Ten U-23 professional and sub-elite soccer players, eight outfield players (age: 20.1 ± 1.5 years old; height: 1.83 ± 0.04 m; total body mass: 76.1 ± 3.6 kg) and two goalkeepers (GK) (age: 20.5 ± 2.1 years old; height: 1.91 ± 0.04 m; total body mass: 77.0 ± 1.4 kg) participated in the study. Five SSGs were performed with 3 min duration and 3 min rest interval. SSG1, SSG2 and SSG4 aimed for ball possession play, while in SSG3 and SSG5, two GK were added, defending regular-size goals. The pitch size changed from SSG1 (16 × 24 m) to SSG2 and SSG3 (both 20 × 30 m) and SSG4 and SSG5 (both 24 × 36 m). All players were monitored using WIMU Pro device during the tasks. Anova One-Way and the post hoc Tukey honestly significant difference were used for analysis of statistically significant differences (p < 0.05) and effect sizes were determined by calculating partial eta-squared. The framework was associated with relevant but steady state internal load fatigue and induce a considerable external load stimulus. GK participation in SSGs should be carefully considered as it seems to have a greater impact on physical load measures when compared to the pitch size manipulation.