Utilize este identificador para referenciar este registo: http://hdl.handle.net/10400.15/1703
Título: Stationary roller versus velodrome for maximal cycling test: a comparison
Autor: Brito, João
Lopes, Luís
Conceição, Ana
Costa, Aldo
Louro, Hugo
Palavras-chave: Cycling
Oxygen Consumption
Heart Rate
Power Output
Cadence
Data: 2014
Editora: Faculty of Education. University of Alicante
Citação: Brito, J., Lopes, L., Conceição, A., Costa, A., & Louro, H. (2014). Stationary roller versus velodrome for maximal cycling test: a comparison. Journal of Human Sport and Exercise, 9(1), 7-16. doi:http://dx.doi.org/10.4100/jhse.2014.91.02
Resumo: The present study aimed to compare the acute cardio-respiratory responses of elite cyclists to a maximal progressive exercise carried out in two different conditions: in a laboratory (using a braked roller) and in an uncovered velodrome. In both testing conditions, ten elite male cyclists (age, 22.3 ± 3.9 years) performed a maximal discontinuous progressive test of 6 minutes per level with 150 W of initial load and increasing 50 W at each level until exhaustion. The heart rate and the ventilation parameters were measured breath-by-breath using a portable metabolic cart gas analysis system with telemetry data transmission. In the first 4 levels of effort, no significant differences were found between the two test conditions regarding VO2, (p=0.193), heart rate (p=0.973) and pedaling cadence (p=0.116). Comparing the maximum values achieved by each athlete in both exercise conditions, significant differences were found for heart rate (p=0.008) and pedaling cadence (p=0.005) but not for VO2max and peak power. Each variable showed a strong correlation between both assessements (VO2, r=0.984, p=0,000; heart rate, r=0.944, p=0.005; pedaling cadence, r=0.900, p=0.014). The amount of variability explained by the linear regression model for both cardio-respiratory parameters also showed a good fit value close to one (VO2max,r2=0.968; heart rate, r2=0.892). Our results suggest that identical cycling protocols conducted in different testing conditions with the same bike leads to equivalent performance but significantly different pedaling cadence and heart rate responses.
Peer review: yes
URI: http://hdl.handle.net/10400.15/1703
DOI: 10.4100/jhse.2014.91.02
ISSN: 1988-5202
Versão do Editor: http://www.jhse.ua.es/article/view/2014-v9-n1-stationary-roller-versus-velodrome-for-maximal-cycling-test-a-comparison
Aparece nas colecções:Artigos em revistas internacionais - ESDRM

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
Brito et al,2014. Stationary roller vs velodrome maximal cycling test. ljhse_Vol_9_N_I_7-16.pdf345,43 kBAdobe PDFVer/Abrir


FacebookTwitterDeliciousLinkedInDiggGoogle BookmarksMySpace
Formato BibTex MendeleyEndnote Degois 

Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.